System
- Number of printing units: up to 20
- Maximum web speed: 1,200 m/min
- Format length: 50 – 6,000 mm
- Applications: Gravure printing, flexo printing, offset printing, screen printing, processing units
- Measurement methods: web-web 1, web-web 2, web-cylinder
- Control algorithms: Gravure, Offset, Insetter
- Interfaces: SMARTData, Ethernet, PROFIBUS, PROFINET
Sensors
- Variations:
RSH fiber optics, 1- and 2-channel
RSH digital
RSH UV
RSC matrix camera - Measuring resolution: ± 5 μm
- Measuring frequency: 30 Hz
- Register marks: Wedge marks, block marks, dot marks, special printing features
- Materials: Paper, foil, metallized substrates (opaque, transparent, reflective)
- ATEX approval (only RSH fiber optic sensor): <Ex> II 2 G [Ex op is T4 Gb] IIB